Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Design for fire

Which of the following is/are not considered a major risk factor in fire in BS9999, the new British Standard published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents?

Whether the occupants of the building are familiar with their surroundings.
Whether the occupants of the building are likely to be asleep
Where there is not a fire station nearby
The height of the building

Structural steel in single storey buildings does not generally require fire protection. Which of these situations is not an exception to that rule?

The steel is in an external wall which must retain stability to prevent fire spread to adjacent buildings
The steel forms part of a compartment wall or the enclosing structure of a protected zone
The building contains a valuable cargo which must be protected and so the building must be protected against collapse
The steel forms part of a separating wall

Which of the following statements is correct?

The standard fire test is always a good representation of what happens in a real building fire.
A standard fire test on composite steel deck floors is a good indicator of how these floors will behave in real fires.
Continuous composite steel deck floors generally have much greater strength in fire than is indicated by the standard fire test on isolated elements.
The standard fire test is unsafe.

Which of the following statements is not always correct?

Fire safety engineering can provide an alternative approach to fire safety to that given in Government published documents such as Approved Document B.
A fire engineering approach should always be considered in large buildings.
For some buildings, the provisions of documents such as Approved Document B for the design of fire precautions may not be adequate and a fire safety engineering approach may be the only viable way to a satisfactory standard of fire safety
Fire safety engineering has wide applications in finding solutions to particular problems in the design of fire precautions

Which of the following are commonly used to provide fire protection of structural beams and columns in the UK?

Boards
Sprays
Thin film intumescent coatings
Reinforcing steel and concrete between the flanges

Which of the following is/are true?

Approved Document B must be used in the design of fire precautions in England?
The use of Approved Document B for the design of fire precautions in buildings in England is deemed to satisfy the requirements of the Building Regulations.
It is not necessary to use Approved Document B for the design of fire precautions in England if it can be shown that you have met the requirements of the Building Regulations in some other way.
The use of Approved Document B does not guarantee that all buildings will be safe in fire

Which of the following have been used as compensatory features where beams have been designed to be unprotected in composite steel deck construction?

Increased numbers of shear studs
Increased mesh size
Flexible connections to accommodate increased deflections
Changing the floor to precast plank

What is the meaning of time equivalent in fire engineering?

It is the severity of a fire in a compartment in terms of exposure to a standard fire test
It is the time in minutes at which the fire in a compartment will burn above 600°C
It is the period for which a fire will burn based on times measured in other, equivalent, compartments
It is the period of time which is required for the fire brigade to attend and extinguish a compartment fire.

How does an element of construction demonstrate that it can perform a fire resisting function if required?

Through trial and error in real building fires
Through a detailed theoretical study
Via a fire test carried out in accordance with a standard acceptable in the country in which that element is to be used
Via tests carried out in the manufacturer's own furnaces

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets