Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Fire and steel construction

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Use of the advanced methods of structural fire engineering developed from the Cardington fire tests will usually lead to what?

No fire protection on the beams or columns
No fire protection on any of the beams
No fire protection on most of the secondary beams
Reduced fire protection on the secondary beams.

Which one of the following statements is correct?

The standard fire test is a good representation of what happens in a real building fire.
A standard fire test on composite steel deck floors is a good indicator of how these floors will behave in real fires.
Continuous composite steel deck floors have much greater strength in fire than is indicated by the standard fire test on isolated elements.
The standard fire test is unsafe.

Fire protection thickness is a function of the section factor of the beam or column. Which of these statements are correct?

The section factor is the cross sectional area in square metres divided by the heated perimeter in metres.
The section factor is the heated perimeter in metres divided by the cross sectional area in square metres.
Short stocky sections will typically have higher section factors than tall, skinny sections.
Fire protection thickness decreases as section factor decreases.

The maximum period of fire resistance required in Approved Document B to help meet the requirements of the Building Regulation is?

60 minutes
90 minutes
120 minutes
240 minutes

Which of the following describes the building at Cardington in which the major fire test programme was carried out between 1994 and 2003?

Non-composite steel frame with precast planks
Steel frame with Slimdek floors
Steel frame with composite steel deck floors
Post tensioned flat slab

Which of the following statements are correct?

Approved Document B must be used in the design of fire precautions in England
The use of Approved Document B for the design of fire precautions in buildings in England is deemed to satisfy the requirements of the Building Regulations.
It is not necessary to use Approved Document B for the design of fire precautions in England if it can be shown that you have met the requirements of the Building Regulations in some other way.
The use of Approved Document B does not guarantee that all buildings will be safe in fire.

A new British Standard, BS 9999, has been published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents. Which one of these best describes the fundamental principle behind its development?

Based on an understanding of the factors that create risk in fire
Based on conservative experience
Based on European approaches to the design of fire precautions in buildings
Based on an averaged approach from across the regions of the UK

What was given as the common maximum dry film thickness for thin film intumescent coatings that can be applied in one pass?

1200 microns
1500 microns
1800 microns
2000 microns

How does an element of construction demonstrate that it can perform a fire resisting function if required?

Through trial and error in real building fires
Through a detailed theoretical study
Via a fire test carried out in accordance with a standard acceptable in the country in which that element is to be used
Via tests carried out in the manufacturer’s own furnaces