Difference between revisions of "Design for fire quiz"

From SteelConstruction.info
(Created page with "Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz...")
 
 
Line 3: Line 3:
 
'''Good luck'''
 
'''Good luck'''
 
{{#psy_quiz:design-for-fire}}
 
{{#psy_quiz:design-for-fire}}
 +
 +
[[Category:CPD]]

Latest revision as of 12:11, 12 March 2019

Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Design for fire

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Structural steel in single storey buildings does not generally require fire protection. Which of these situations is not an exception to that rule?

The steel is in an external wall which must retain stability to prevent fire spread to adjacent buildings
The steel forms part of a compartment wall or the enclosing structure of a protected zone
The building contains a valuable cargo which must be protected and so the building must be protected against collapse
The steel forms part of a separating wall

How does an element of construction demonstrate that it can perform a fire resisting function if required?

Through trial and error in real building fires
Through a detailed theoretical study
Via a fire test carried out in accordance with a standard acceptable in the country in which that element is to be used
Via tests carried out in the manufacturer's own furnaces

Which of the following statements is not always correct?

Fire safety engineering can provide an alternative approach to fire safety to that given in Government published documents such as Approved Document B.
A fire engineering approach should always be considered in large buildings.
For some buildings, the provisions of documents such as Approved Document B for the design of fire precautions may not be adequate and a fire safety engineering approach may be the only viable way to a satisfactory standard of fire safety
Fire safety engineering has wide applications in finding solutions to particular problems in the design of fire precautions

Which form of fire protection is most commonly used to fire protect structural steelwork for buildings off-site?

Boards
Sprays
Thin film intumescent coatings
Concrete encasement

Which of the following is/are true?

Approved Document B must be used in the design of fire precautions in England?
The use of Approved Document B for the design of fire precautions in buildings in England is deemed to satisfy the requirements of the Building Regulations.
It is not necessary to use Approved Document B for the design of fire precautions in England if it can be shown that you have met the requirements of the Building Regulations in some other way.
The use of Approved Document B does not guarantee that all buildings will be safe in fire

Which of the following is not a correct conclusion following the Cardington fire tests?

That composite steel deck construction has significantly greater reserves of strength than is indicated by tests of individual members
That columns are critical stabilising elements and must be protected
That all beams supporting composite steel deck floors do not need to be protected in order to prevent structural collapse in fire
That the results are applicable to forms of construction other than steel frames with composite steel deck floors.

In which areas of the UK are sprinklers not mandatory in buildings over 30 metres in height?

England & Wales
Scotland
Northern Ireland
All of the above

A new British Standard, BS 9999, has been published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents. Does BSI describe it as being?

Based on structured risk based design
Based on conservative experience
Based on European approaches to the design of fire precautions in buildings
Based on an averaged approach from across the regions of the UK

Which of the following describes the building at Cardington in which the major fire test programme was carried out between 1994 and 2003?

Non-composite steel frame with precast planks
Steel frame with Slimdek beams
Steel frame with composite steel deck floors
Post tensioned flat slab