Design for fire quiz

From SteelConstruction.info
Revision as of 12:11, 12 March 2019 by Chris.dolling@steelconstruction.org (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Design for fire

The dominant mechanism which enables a composite steel deck floor to enhance its load carrying capacity at large deflections is based on what?

Tensile membrane action in the slab
Catenary action in the beams
Robust connections
Thermal gradients in the slab

Which of the following statements is correct?

The standard fire test is always a good representation of what happens in a real building fire.
A standard fire test on composite steel deck floors is a good indicator of how these floors will behave in real fires.
Continuous composite steel deck floors generally have much greater strength in fire than is indicated by the standard fire test on isolated elements.
The standard fire test is unsafe.

Which of the following have been used as compensatory features where beams have been designed to be unprotected in composite steel deck construction?

Increased numbers of shear studs
Increased mesh size
Flexible connections to accommodate increased deflections
Changing the floor to precast plank

The most widely used source of information for the design of fire precautions in buildings in England is?

Technical Handbook 2
Approved Document B
Technical Booklet E
BS9999

The maximum period of fire resistance required in the documents published by Government across the UK to help meet the requirements of their Building Regulation is?

60 minutes
90 minutes
120 minutes
240 minutes

How does an element of construction demonstrate that it can perform a fire resisting function if required?

Through trial and error in real building fires
Through a detailed theoretical study
Via a fire test carried out in accordance with a standard acceptable in the country in which that element is to be used
Via tests carried out in the manufacturer's own furnaces

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Which of the following are commonly used to provide fire protection of structural beams and columns in the UK?

Boards
Sprays
Thin film intumescent coatings
Reinforcing steel and concrete between the flanges

Which of the following is not a correct conclusion following the Cardington fire tests?

That composite steel deck construction has significantly greater reserves of strength than is indicated by tests of individual members
That columns are critical stabilising elements and must be protected
That all beams supporting composite steel deck floors do not need to be protected in order to prevent structural collapse in fire
That the results are applicable to forms of construction other than steel frames with composite steel deck floors.

In which areas of the UK are sprinklers not mandatory in buildings over 30 metres in height?

England & Wales
Scotland
Northern Ireland
All of the above